Workplace safety audit checklist, including offices

Free workplace and office safety audit checklist from OSHA 29 CFR 1910: floors, stairs, exits, extinguishers, first aid and electrical. Fill in or print.

Updated Sources checked

How often: Walking-working surfaces are inspected regularly and as necessary; portable extinguishers get a monthly visual inspection. How often to run the full audit is set by your organization.

Sections
6
Checks
46
Critical
2
Sources
46

0/40 answered

0%

Answers, comments and photos stay on this device. Nothing is sent to Irada.

Details such as site or building and areas or floors audited are kept with each inspection you run in Irada. The printout has lines for them.

1

Type of area *

When an item fails

Fix a failed walking surface or ladder before anyone uses it again. Hazardous conditions on walking-working surfaces are corrected or repaired before employees use the surface again, and if that can't happen right away the hazard is guarded so nobody can use it [14] [15]. Repairs that affect the structure of the surface are done or supervised by a qualified person [16].

  • A ladder with structural or other defects is tagged "Dangerous: Do Not Use" or with similar words [18] and removed from service until it's repaired or replaced [17].
  • Clear blocked aisles and electrical working space on the spot, since the fix usually takes minutes.
  • Give every other failed line an owner and a date, and close it only after someone has checked the fix.

Run it with your team in Irada

  • Schedule it per site and assign it to the right people.
  • Turn every failed check into a corrective action that someone else verifies.
  • Keep signatures, photos and the full audit history across sites.
Use this checklist Print with your logo

Answers on this page stay on this device; they are not transferred.

Frequently asked questions

What should an office safety audit check?

The same basics as any workplace, scaled to an office: floors free of spills and protruding objects [12], exit routes with nothing stored in them [42], extension cords not used as permanent wiring [34], clear space in front of electrical panels [29], and first aid supplies readily available [1].

How wide does an exit route need to be?

Exit access must be at least 28 inches (71.1 cm) wide at all points [40]. Objects that stick into the route, such as furniture or stored boxes, must not narrow it below the minimum width [41].

How much clear space is needed in front of an electrical panel?

The working space in front of the equipment is at least 30 inches (762 mm) wide, or the width of the equipment if that is greater [28], and it may not be used for storage [29]. The minimum depth of the space is given in Table S-1 of 29 CFR 1910.303 [27].

Can extension cords be used permanently?

No. Flexible cords may not be used as a substitute for the fixed wiring of a structure [34], run through holes in walls, ceilings or floors [35], or run through doorways or windows [36].

What happens when the audit finds a damaged floor or a broken ladder?

A hazardous walking surface is corrected or repaired before anyone uses it again, or guarded until it can be fixed [14] [15]. A ladder with structural or other defects is tagged "Dangerous: Do Not Use" or similar and removed from service [18] [17].

How often do fire extinguishers need to be checked?

A visual inspection every month [5] and a maintenance check every year [6].

Built from 46 official sources

Every check traces to the text it is based on. Read the purpose, how to use it, the rules behind it, what it does not cover and every source.

Guidance, not legal advice. It does not replace the law, the manufacturer's instructions or your organization's competent people, and completing it does not certify that work is safe.