Air conditioner maintenance checklist

Free air conditioner maintenance checklist: filters, coils, condensate drain, electrical checks, readings, and refrigerant handling under EPA rules.

Updated Sources checked

How often: Follow the manufacturer's instructions for the unit, or the interval set by your organization's maintenance plan.

Sections
9
Checks
47
Critical
1
Sources
43

0/38 answered

0%

Answers, comments and photos stay on this device. Nothing is sent to Irada.

Details such as unit number or asset tag and location of the indoor and outdoor units are kept with each inspection you run in Irada. The printout has lines for them.

1

Type of unit *

2

Anyone who will open the refrigerant circuit has passed a technician certification exam from an EPA-approved program *

When an item fails

A failed check on a refrigerant circuit has a deadline attached. The owner or operator calculates the leak rate every time refrigerant is added [15], and leaks have to be identified and repaired within 30 days [17] once the leak rate goes over the threshold, which is 10 percent for comfort cooling [16].

  • Don't vent refrigerant while repairing the unit [8].
  • If a contractor does the work, ask for the service record they're required to provide [18].
  • Failed filters, belts or drains that don't involve refrigerant get an owner and a date like any other maintenance item.

Run it with your team in Irada

  • Schedule it per site and assign it to the right people.
  • Turn every failed check into a corrective action that someone else verifies.
  • Keep signatures, photos and the full audit history across sites.
Use this checklist Print with your logo

Answers on this page stay on this device; they are not transferred.

Frequently asked questions

Do I need EPA technician certification to maintain an air conditioner?

The requirement applies to a person who could reasonably be expected to violate the integrity of the refrigerant circuit [26]. That person must pass a certification exam offered by an approved technician certification program [25]. The EPA rules apply to anyone maintaining, servicing or repairing appliances with these refrigerants [4].

Is it legal to release refrigerant from an air conditioner?

No. Knowingly venting or otherwise releasing refrigerant during maintenance, service, repair or disposal is prohibited [8]. Work on the circuit uses recovery or recycling equipment with EPA certification for that refrigerant and appliance type [9] [10].

Do EPA leak repair rules apply to my air conditioner?

It depends on the refrigerant and the full charge. Appliances with 50 lb or more of class I or class II refrigerant fall under 40 CFR 82.157 [14]. Appliances with 15 lb or more of an HFC or a substitute with a global warming potential above 53 fall under 40 CFR 84.106 [27] [28], except those used for residential and light commercial air conditioning [30]. Commercial split systems and packaged rooftop units are examples of comfort cooling appliances [5].

Is a window air conditioner a "small appliance" under EPA rules?

Yes. A small appliance is fully manufactured, charged and hermetically sealed in a factory with 5 lb or less of refrigerant [6], and the definition lists room air conditioners, including window and portable air conditioners, and packaged terminal air heat pumps [7]. Refrigerant is still recovered before a small appliance is opened [12].

Do I have to lock out an air conditioner before maintenance?

OSHA's lockout/tagout standard covers servicing and maintenance where unexpected start-up or release of stored energy could cause injury [1], and the equipment is isolated from its energy source and made inoperative first [3]. The standard does not apply to cord-and-plug equipment when the hazard is controlled by unplugging it and keeping the plug under the exclusive control of the person doing the work [2].

What records should the technician leave after adding refrigerant?

For appliances covered by the leak repair rules, a person other than the owner who services the appliance gives the owner a record of the work [18] [42], and under 40 CFR 84.106 records are kept for at least three years [35]. The record covers the identity and location of the appliance [19] [36], the date of the work [20] [37], the parts serviced [21] [38], the type of work on each part [22] [39], the name of the person doing it [23] [40], and the amount and type of refrigerant added [24] [41].

Built from 43 official sources

Every check traces to the text it is based on. Read the purpose, how to use it, the rules behind it, what it does not cover and every source.

Guidance, not legal advice. It does not replace the law, the manufacturer's instructions or your organization's competent people, and completing it does not certify that work is safe.